Project Calculators

Units

Paint

Walls, ceilings, primer

Coats

Typical figure. The can label has the exact one.

Door and window size

Typical figure. The can label has the exact one.

The sizes you can buy, separated by commas.

Flooring and tile

Boxes, tiles, grout

Waste allowance
%
Material

From the box label.

Tile

Mulch, soil and gravel

Bulk or bagged

Material

Concrete

Slabs, footings, post holes

%

Ready-mix producers advise 4 to 10%.

Drywall

Sheets, screws, tape, compound

%
Framing spacing
Door and window size

Deck boards

Boards, joists, fasteners

Boards

A nominal 6 in board is 5 1/2 in wide.

A deck construction guide recommends about 1/8 in.

Framing and fasteners

A deck construction guide specifies two.

Figures and sources

Paint

Most paints cover 300 to 400 sq ft per gallon, about 7.4 to 9.8 m² per liter. A paint recycling program suggests 350 sq ft per gallon for a rough estimate when the label is unknown; the paint and primer defaults use it.

Flooring and tile

The 10% extra for a straight lay and 15% for a diagonal lay are rules of thumb; herringbone and other patterns often take more. Grout follows a tile-setting manufacturer's published formula: (A + B) ÷ (A × B) × C × D × 1.6 gives kilograms per square meter, with tile length A, width B, thickness C and joint width D in millimeters.

Mulch, soil and gravel

Gravel weight uses the bulk density of dry, compacted coarse aggregate from a concrete-industry reference: 80 to 120 lb per cu ft (1,280 to 1,920 kg/m³). Tons are short tons of 2,000 lb.

Concrete

Bag yields are manufacturers' published figures for bagged concrete mix: 0.30 cu ft for 40 lb, 0.375 for 50 lb, 0.45 for 60 lb, 0.60 for 80 lb and 0.675 for 90 lb; 10 L for 20 kg and 15.1 L for 30 kg. Yields differ between products; check the bag. Guidance from ready-mix producers is to order 4 to 10% more than the calculated volume. The calculation assumes square posts that stand on the bottom of the hole.

Drywall

A gypsum construction handbook gives, per 1,000 sq ft of board: about 1,000 screws for walls with framing 16 in apart or 850 at 24 in, 370 ft of joint tape and 138 lb of all-purpose ready-mixed joint compound. The same handbook spaces screws 12 in apart on ceilings and 16 in on walls, so ceilings are counted at 4/3 of the wall rate. The 10% sheet allowance is a rule of thumb.

Deck boards

A prescriptive deck construction guide specifies two nails or screws per board at every joist, a gap of about 1/8 in between boards, and at least three joists under every piece. Boards are cut so that every joint falls on a joist. Dressed softwood lumber is smaller than its nominal size: a nominal 4 in piece is 3 1/2 in and a nominal 6 in piece is 5 1/2 in.

Conversions

1 ft = 0.3048 m and 1 in = 25.4 mm exactly; 1 US gallon = 3.785411784 L; 1 lb = 0.45359237 kg; 1 cu yd = 27 cu ft.